  • 1. BioMicroLab Laboratory Automation for Sample Management
  • 2. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA For pharmaceutical, biotech, agricultural and research laboratories that require flexible systems for growing laboratories, BioMicroLab offers modular systems to accelerate sample management workflows. BioMicroLab Product Line
  • 3. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA BioMicroLab Product Line Tube & Vial Handlers Lab Tools & Software Standalone Volume Detection Barcode Scanners Label Printers & Applicators • VolumeCheck 50 • VolumeCheck 100 • VolumeCheck 384 • XL20 (20 rack capacity) • XL9 (9 rack capacity) Benchtop Tube & Vial Handlers • XL200 (30 rack capacity) • XL100 (20 rack capacity) SampleScan line includes: • High-Speed Scanners • Frozen Rack Scanners • Single Tube Readers • Rack ID scanners • Standalone or • Integrated with a tube handler • Capper / Decapper • 5-Place Balance • Ionizer • Rack Thawing Station • And more
  • 4. 925-689-1200 | sales@biomicrolab.com | www.biomicrolab.com XL9 & XL20 Benchtop Tube Handlers Re-array ● Scan ● Weigh ● Label Best in Class • Walk-away tube handling • Gravimetric volume detection • Print and apply labeling XL20 XL9
  • 5. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA • BioMicroLab’s XL Series of reliable, flexible and affordable robotic pick and place systems automate critical sample management tasks such as:  Organizing  Reformatting  Accurately tracking samples  Labeling tubes • XL9 & XL20 are fully compatible with LIMS systems and with multiple labware formats. • Choose and order your XL Series platform with the capacity and modules right for your lab’s application. XL9 & XL20 Benchtop Tube Handlers Reliable, Flexible and Affordable
  • 6. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Choose the Rack Capacity and Options to Enhance Your Workflow..
  • 7. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Capabilities Barcode Decoding 4-Place Automated Balance Tube Labeler & Printer LIMS Integration LevelCheck DMSO Hydration Check
  • 8. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA • Compound sample library management  Re-array sample libraries  Track sample library volume / inventory • QA/QC  Confirm sample volume with analytical balance and/or LevelCheck • Cherry pick tubes for efficient liquid handling • Confirm DMSO Hydration • Save freezer space by consolidating tube rack samples • Print and apply human readable text and barcode labels (with the XL LabelPro module) Great Benchtop Robot Easily integrate with fully automated sample stores XL9 & XL20 Benchtop Tube Handlers Applications
  • 9. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Genomic BioBanks Central Compound Storage Libraries  Orders for compounds or samples placed by research scientists  Samples cherry picked with XL20 robot • Ensures accuracy • Built-in error handling  Automation provides data files to update LIMS system Results 2D barcoding and robotics provide speed and efficiency in managing libraries of samples XL9 & XL20 Benchtop Tube Handlers Core Facility Sorting Applications
  • 10. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Workflow Application Researcher Sends Request for Samples 2D barcoded tubes Create plates of targeted compounds Tube Picking – Re-arraying LIMS Database Sample Compound Store Sample Store Consumables Researcher performs assays 2D Reader Verify tube ID and position
  • 11. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Consolidation of compound samples into fewer racks prior to HTS Screening or Liquid Handling operations  Work list of compounds for HTS screening generated from data base  XL20 picks from multiple source racks and transfers to target racks Results More productive and efficient use of liquid handler XL9 & XL20 Benchtop Tube Handlers Application – HTS Sorting
  • 12. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Cherry Picking for HTS Screening Scientist places order for samples Sample Compound Store 2D barcoded tubes Sample Store Consumables Create plates of targeted compounds Tube Picking – Re-Arraying Liquid Handling – Assay Screening Efficient compound screening Volume Verification Verify well volumes to update LIMS system Update LIMS with rack ID and tube position LIMS Database
  • 13. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA 2D Barcode Reader module  Integrated single tube reader  Decodes 2D marked tubes while sorting Analytical Balance module  Captures tube weight  0.0001g readability  Software application specific to net weight capture of tube sample LevelCheck module  Non-contact sensor detects sample meniscus and returns volume data. Label Printer & Applicator module  Label up to 180 tubes per hour with 1D barcodes, 2D barcodes and human readable text Software  Work list based operation  Windows software allows easy LIMS integration XL20 Benchtop Tube Handler Specifications Includes Instrument, Software, Manual Dimensions* 28.5”W x 21”D x 16”H 724mm x 533mm x 406mm Weight* 60 lbs (27kg) Environment 10°C - 40°C, 10-90% RH Standard Model -4°C - 40°C, 10-90% RH Cold Room Model System Windows 8, 7, Vista, 1GB Ram, 2.2+Ghz processor, Serial and USB Ports * Varies slightly depending on automation modules
  • 14. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA 2D Barcode Reader module  Integrated single tube reader  Decodes 2D marked tubes while sorting Analytical Balance module  Captures tube weight  0.0001g readability  Software application specific to net weight capture of tube sample LevelCheck module  Non-contact sensor detects sample meniscus and returns volume data. Label Printer & Applicator module  Label up to 180 tubes per hour with 1D barcodes, 2D barcodes and human readable text Software  Work list based operation  Windows software allows easy LIMS integration XL9 Benchtop Tube Handler Specifications Includes Instrument, Software, Manual Dimensions* 18”W x 17”D x 16”H 457mm x 432mm x 406mm Weight* 40 lbs (18kg) Environment 10°C - 40°C, 10-90% RH Standard Model -4°C - 40°C, 10-90% RH Cold Room Model System Windows 8, 7, Vista, 1GB Ram, 2.2+Ghz processor, Serial and USB Ports * Varies slightly depending on automation modules
  • 15. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Throughput Examples Mode of Operation XL9 or XL20 Tubes per hour Sort only 700 Sort and 2D Decode 500 Sort, 2D Decode, and Weigh ~250 Sort and Weigh ~300 Sort, 2D Decode and LevelCheck 350-400 Sort, 2D Decode and DMSO Check 350-400 Sort and Label 180 Please call to review your application for tube processing throughput . Both the XL20 and XL9 have the same operational throughput – only the rack capacity is different. XL20 XL9
  • 16. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA • Scans and decodes 2D barcoded tubes / vials • Captures 2D barcode while processing tubes • Module does not use a tube rack nest Typical Application Tube sorting and re-arraying XL9 & XL20 Benchtop Tube Handlers 2D Camera Option
  • 17. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA • Determines the volume of samples stored in tubes while sorting, re-arraying and capturing 2D barcodes • Analytical balance measures 300 tubes per hour (~3 racks) • Optional: XL Ionizer available to dissipate electrostatic charge from plastic tubes • Weight data is output in .csv file • Utilizes 2 rack positions on the sorting platform Typical Application Gravimetric volume tracking – Sub 5µL accuracy XL9 & XL20 Benchtop Tube Handlers Automated Balance - Volume Detection Option Analytical Balance Specifications Weighing Range 60g Readability 0.0001g Reproducibility +/- 0.0001g Communication <= +/- .0002g Response time (average) <= 2 sec
  • 18. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA • High-Speed, non-contact volume detection • Determines the volume of sample in tubes while sorting, re-arraying and capturing 2D barcodes • Uses a non-contact sensor to detect the sample meniscus and returns the volume data • Camera captures the sample image • Measures 375 tubes (~4 racks) per hour • Accuracy: +/- 10 μL to 15μL • Utilizes one rack position on the sorting platform • Easily upgrade your lab’s existing system XL9 & XL20 Benchtop Tube Handlers LevelCheck - Volume Detection Option LevelCheck is installed in rack position #5 on an XL20 sorting platform
  • 19. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Fully automated measurement of hydration level of DMSO  Accuracy: ±1% of hydration level of DMSO  Measurement time: <50 ms  Solvent concentration measurement range: 70% - 100%  XL9 or XL20 provides multiple robotic operations: 2D barcode reading, weighing, and concentration readings • XL20 throughput: 15 minutes per rack  Uses one Tube Handler deck position  Full upgrade kit available from BioMicroLab  Compatible labware • Polypropylene with 8mm diameter • Matrix/Micronic 96 well tubes XL9 & XL20 Benchtop Tube Handlers DMSO Hydration Check Option Tube Dowser Data Captured with XL Software
  • 20. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Features • Print 1D & 2D barcodes with human readable text • Print identical or unique labels, or apply pre-printed labels • 300 – 600 dpi thermal printer with ~1,2000 label capacity • Fast start-up and unattended operation • All electric operation; no compressed air • Small footprint with convenient design (adds 10”) • Thermal ribbon and label spool are easily accessed which provides simple maintenance • Labeling easily integrates with all other XL Series tube processing operations, such as cherry-picking, barcode decoding, re-arraying and volume detection • Available standalone or integrated with an XL Series Tube Handler XL9 & XL20 Benchtop Tube Handlers Labeling Option Upgrade your existing XL Tube Handler on site The XL9 and XL20 label up to 180 vials per hour (18 seconds per label). XL LabelPro shown here with XL20.
  • 21. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Labels  1,200 – 2,000 label capacity (varies with label size)  Wide variety of label material including plastic/permanent acrylic (CryoLabel®)  Thermal printer ribbon resin is rated super premium for DMSO and alcohol chemical resistance (T84/T85)  Temperature range: LN2 to 200°F  Labels designed for liquid nitrogen (-196°C) and freezer (-80°C) environments Labware Compatibility SBS standard tubes from major manufacturers 96 well tubes XL9 & XL20 Benchtop Tube Handlers Labeling Option (continued) The XL9 and XL20 label up to 180 vials per hour (18 seconds per label)
  • 22. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Software  User-friendly software  Easy to repeat previous labeling tasks with project based software  Design your label with text and/or barcodes ; easily data merge  Merge data from external sources (.csv or .xml)  Input file can control all tube movement operations (re-array, volume detection, liquid handling, barcode detection, labeling, etc.)  Output file is user-definable (.csv)  LIMS integration ready XL9 & XL20 Benchtop Tube Handlers Labeling Option (continued)
  • 23. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Included with all Tube Handlers:  BioMicroLab XL Series Work List Manager Software • Windows Based software (8, 7, Vista) • Manages sample processing modes and robotic operations For labs developing in-house custom programs to control instrument operation, integrate other robotics or streamline the processing of input and output files, we offer these options:  SDK Toolkit  ActiveX Toolkit  XL Plus (Primarily used with XL100/ XL200 liquid handling module) XL9 & XL20 Benchtop Tube Handlers Software – Overview Work List Manager software
  • 24. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA 1) Work List Based Re-array applications • Sequential  Racks are processed in work list order • Random  Racks are processed in random order 2) No Work List Required Pick and place vial from same location • Tare/Gross Weigh  Tare and gross weight of vials  Streamlined weighing mode • Data Collection Mode  Typically used to collect linear barcodes or vial weight XL9 & XL20 Benchtop Tube Handlers Software – Modes of Operation
  • 25. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Work List Mode Operation Query LIMS Database for Sample List Create file with commands Input (.csv) XL Tube Handler imports information Tube Handler processes tubes Output (.csv) Import file into LIMS Database XL Tube Handler creates an output file for each rack
  • 26. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Work list example  Source Rack ID  Source Tube Location  Expected Tube 2D barcode (optional)  Target Rack ID  Target Tube Location XL9 & XL20 Benchtop Tube Handlers Software – Input Work List Example
  • 27. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Software – WorkList Processor (Re-Array Mode) Source Rack, Tube Position, Barcode, Target Rack, Tube Position SRC_000, H03, 0011553474, TGT_001, D12 SRC_000, G03, 0011553437, TGT_001, H03 SRC_000, F03, 0011553466, TGT_001, D02 Input file (Comma Delimited Text) Cumulative Log File Individual Target Rack Files All Target Rack Files in a Single File 3 Output Options:
  • 28. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA • Main Processing Screen  Work list controlled movement of tubes  Confirms tube ID from work list with captured 2D data  Captures image of 2D barcode for error handling  Sample weight capture displayed  Software generates Job ID for tracking in your LIMS system  Start, Stop, and Pause XL9 & XL20 Benchtop Tube Handlers Software – Features Click to import work list
  • 29. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Work List Software  Assignment of racks to XL20 platform locations  Color coded interface guides user through tube rack loading process  Supports input from hand- held barcode scanner  Works dynamically for job processing with extended number of racks XL9 & XL20 Benchtop Tube Handlers Software – Tray Setup Work List Manager software Tray Set-up Screen
  • 30. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA • To Start - press job initiator button • Can view live video vs. captured bitmap  Barcode Read  Returns decoded barcode • Status column  OK  Barcode mismatch • Weight column  Returns weight XL9 & XL20 Benchtop Tube Handlers Software – Features Captures data while processing tubes Work List Manager software
  • 31. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Software – Output Files Individual Target Rack Files All Target Rack Files in a Single File Cumulative Log File  File names assigned using rack ID numbers  Separate files created for each target rack  Old data is overwritten by current data  File names specified by user  Individual target rack files are concatenated to form this file  File names assigned using rack ID numbers  Separate files created for each target rack  Data is never erased; new entries append dynamically Example Output Data JobID, Tube, Barcode, Weight 120711090014, A01, 0119177183, 636.0 120711090014, A02, 0119177161, 637.3 120711090014, A03, 0119177181, 626.7 120711090014, A04, 0119177180, 631.3 Common Features • All contain comma delimited text • User specified save locations • Headers are optional
  • 32. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA Generates LIMS output file for use by sample tracking systems  Operator can pre-determine content of output file  Output file can be placed in folder or on a network drive  Example of Work List Processing Mode Output XL9 & XL20 Benchtop Tube Handlers Software – WorkList Mode Output File
  • 33. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Software – WorkList Mode Output File Example
  • 34. www.biomicrolab.com 925-689-1200 sales@biomicrolab.com 2500-A Dean Lesher Dr, Concord, CA 94520 USA XL9 & XL20 Benchtop Tube Handlers Software – Error Handling Error handling for operations  Tube Movement • Picking Tube • Placing Tube  Bar Code Decoding • Barcode Mismatch • Decode failure Features  Selectable by the operator  Audible Alarms
  • 35. 925-689-1200 | sales@biomicrolab.com | www.biomicrolab.com Contact BioMicroLab BioMicroLab has been designing lab automation equipment since 2001 and our team has a 20-year track record in manufacturing material handling products from our Northern California facility. BioMicroLab has installed 100s of automated tube handlers and 1,000s of sample management devices at biotech and pharmaceutical companies, hospitals, universities, genomic research facilities and biobanks worldwide. Online www.biomicrolab.com Email info@biomicrolab.com Tel (925) 689-1200 Fax (925) 689-1263 Mail 2500-A Dean Lesher Drive Concord, CA 94520 USA We are committed to offering reliable, results-oriented and cost-effective solutions to our customers.
  • 36. BioMicroLab, Inc. | 2500-A Dean Lesher Dr. Concord, CA 94520 USA 925-689-1200 | sales@biomicrolab.com | www.biomicrolab.com Thank You We appreciate your consideration of our products and hope we have the opportunity to help you accelerate your workflow.
  • Search Related
    We Need Your Support
    Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

    Thanks to everyone for your continued support.

    No, Thanks